Revit change face based family to non hosted. Bam it is gone and you have a non host family. Just constrain elements properly to the face of the host wall face in the family. For new families, I see zero reason to not use face-based. Oct 2, 2019 · The window family is created in a window family template that default is a wall host family, so you cannot just turn it into a non-hosted family. Select Oct 8, 2023 · Users reported that face based families lose their host and are shifted when the hosting link is reloaded in Revit. Jun 6, 2022 · Adding Revit face based and plane based families in Atkore tool bar. What i want to achieve is to use reference planes to do the same (in other words: I would like to use a reference plane as a host for my face-based families). com/ Jan 7, 2016 · Here is an easy workflow to convert a wall based Revit family to faced based Dec 13, 2017 · I would not use a face based family. Face based is more flexible should you need this place the family on a face more than just a wall in the model, such as a wall in a link, or a face of a mass, etc. Start another new Project, and Link the previous Project into this one. Jun 1, 2017 · Select the elements from the face based families (geometry, reference planes, parametric dimensions), CRTL+C, and CTRL+V align to view on the non-host family. If needed a detail drawing can assist to clarify the situation/dimensions. Is there any benefit to using light fixtures that are Ceiling Based vs. but for some reason the hose reel (either nesting, or copy/paste) was 90°F off and the family stuck into the room. If you using face base, you have to construct your model on floor face surface. Feb 18, 2022 · Hi there, I’m placing Revit family instances from Grasshopper via the Component by Location module. There are some cases where un-hosted is better, though. And I made a fake Apr 7, 2014 · In relation to a 'face' based family (probably others as well) what function does the 'Default Elevation' serve? Whilst I obviously understand what the both words mean, there seems to be no relationship between any family created using one of the templates and any arbitary value assigned to the parameter. Aug 3, 2023 · A ceiling hosted family will ONLY attach to a ceiling and the ceiling has to exist in your model - it won't work with ceilings in linked files. Apr 9, 2024 · I nested my wall-hosted casework inside of a wall-hosted light fixture family. :crazy: I tend to like to keep my standard families built completely consistently. Further adjusting and tweaking is still required, but it is often the best option compared to rebuilding content from scratch. I have a question regarding the host of the family in revit. Global Parameter . 2. I have experimented with the work-plane-based checkbox. but I have a family that is not hosted (blank for the host). Dec 17, 2021 · Hello, I am trying to convert this trench gutter from Revit City from a floor-based family to a face-based family, using this guide. However, when the line-based family is hosted inside of a, say, wall hosted family, the two point placement is lost. Change the category of the element to something that can be copy monitored after linking; Link the file with the hosted family to another project then copy monitor the element; This will convert the family into Face based element; Here is a Screencast of technique I'm using to convert face hosted family Aug 24, 2021 · I would start with non-host and change it to door category. Create. Jun 1, 2017 · 1. and produce a non-hosted copy is as follows: Place an instance of the family you want to hack in the drawing area. However, that wasn't an option here because it was the only ceiling on the floor at its height. Open up the family you need to convert to Apr 30, 2012 · Is it possible to change a family from Face based to level based. I believe this is what you are wanting. I think if there was just an option within the family editor that we could adjust it would be best. Thus never the two shall meet (and both function correctly). Shared Parameter. based families are a legacy feature before face-based was a thing. This can be tricky to model if you are used to construct door using elevation. Feb 1, 2017 · Hello @ASCunningham,. 🔰In this video, we will learn how to Convert #Revit Hosted Families to Face Based Family or Non-Hosted Family In the modelling process, i A convoluted process where you copy/monitor the hosted family which creates a face-based version of the family. ive got a FCU family that is work plane based i cannot offset this elevation from the workplace so its stuck to whatever workplace is there. " Note: The same behavior May 13, 2022 · See attached images. Re-constrain and add whatever is missing. Jul 19, 2017 · Normally, I will host to a different ceiling of the same height in the same RCP, then move the fixture to the ceiling I want to be hosted to, since Revit will properly rehost the fixture even if you can't choose the ceiling when picking a host. I've copy monitored architect's electrical fittings into our model and done an automatic mapping with our fixtures. I pass points and the host wall to 'Component by location" but the instantiated families come in on the wrong side of the wall. Saveas the family and link it into the project you originally wanted it in, your family is now level hosted. Jul 26, 2016 · Recently there was a need for a custom piece of Revit family casework which was inadvertently made using a wall-based family template. Wall-based families won't attach to linked walls, Ceiling-based families won't attach to linked ceilings, etc . And I’ve tried a few different family categories. Oct 27, 2017 · XYZ location = new XYZ(X, Y, Z); IList<Reference> sideFaces = HostObjectUtils. Thank you in advance, Drew (Quarantine Day 66)Today I am going to show you something about the void in the face-based family. When trying to group the families which shift, a warning is displayed: "Instance origin does not lie on host face. You can save the face-based family as an RFA file. ByFace” node, but i can only use surfaces from elements or system-families (like walls). Instance will lose association to host. For wall mounted object, such as trash receptacle, recess fixture that need to cut out the host (wall), most people (including myself) will go for face based other than wall Jan 20, 2009 · I have searched, and I don't think that anyone has asked this question yet. Since I cant change their titles, one shows the revit family hosted on the wall, one (mostly gray) shows the annotation in the family itself, and the other shows the annotation setting of the family. Open 2 windows, side by side, a plan view showing a section, and that same section view, with extents that are only a walls width. I don’t want to change the type! I want to change the whole family using dynamo. unfortunately, I am unable to place that family on my ceiling in the project. If a family is started as “wall-based”, it cannot simply be changed to non-hosted. Face-based families also have two key characteristics that are important to MEP workflows. Or use a work plane based family in stead of face based. If I create a face-based receptacle that will always be hosted on a wall (or something vertical), I'd like it to default to the vertical face, not a non-vertical face. Please help : Changing Non- Host Revit Family to Face based or Wall BAsed Host Family I know how to convert a wall or ceiling based family to a face based family. Specifically, the family instances are wall-hosted. Jul 27, 2018 · Good afternoon, I'm trying to convert an undermount sink model I have from a hosted family to a face-based family to automatically cut a countertop when placed. Once the setting has been saved, this option is greyed. I would love to place the trench gutter directly onto a Pad. Then open the result family, select the host extrusion and change the thickness to 0. Dec 3, 2012 · You can convert a Wall-Based Family to a Face-Based Family with the following steps: 1. b. How to place a ceiling light fixture in a Revit model that has no ceiling. The problem is that it won't insert into a view where the Architectural elements are from a linked file rather than having been created in the file I'm working in. For face based, you might need to double nest to rotate the 90 degrees: nest the loose into a face based sticking out of the surface, then stick that family to the sill reference plane of the face based, and link relevant parameters through both Mar 22, 2018 · If you need LinkElements your workflow seems sensible. See Creating a Work Plane-based Family. I loaded the light fixture outer family into a small dummy project; I loaded that project into an empty project; I used copy/monitor to convert my outer light fixture family to a face-hosted family; The nested casework families were also converted to face-hosted. GetTopFaces(floor); Reference inferiorFaceRef = sideFaces[0]; XYZ refDir = new XYZ(0,0,1); FamilyInstance instance = document. As the screenshot shows, the delete options are grayed-out. We can have a face-based family that cut void on any surfac About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Feb 1, 2012 · Question: After placing your hosted Air Terminals on the face of the linked ceiling, what does "Host" read under its Properties? I cannot get a face-based fixture to host to a linked ceiling in this project, period. Use a Mechanical Equipment or Fitting family template: it can be rotated however you want in the project. Rather than painfully reconstructing the family in a new face based model, you can nest the ceiling or wall based family in a new face based model. CAD Point Internet Site: http://cadpoints. An alternative would be to create a dictionary of the LinkElements where the ID is the key and instance is the value, then use the ID’s from the ray bounce result as value keys to regather the corresponding LinkElements from the dictionary. There has to be a straight forward relationship between the family and the project. Jun 14, 2018 · You can't change how the family itself relates to the host while working in a project. Access my courses at:https://www. Convert Between Hosted Wall, Face, Ceiling, Floor, and Non-Hosted Families in Revit. 1. Aug 10, 2011 · You can change non-hosted to hosted by turning on "Workplane Based" in the family options. I don't have the desire to re-create the exact same family just to make it face based. &nbsp;I need to understand this when nesting such families. Hence using face hosted or workplane based families for MEP so that they will attach to the face of the ceiling or to a workplane aligned to the underside of the ceiling, rather than embedding into a ceiling. then i have checked work based option in a family and tried, now i stuck with another weird problem that r Jun 1, 2017 · I have created a face based hosted family. The family editor needs to assume what will be the host and everything else needs to be set according to that. You can load the old family into a model, and then using the Component command attache the ceiling based family to the face of the face based family. I noticed there is no face-hosted plumbing template, so i use a generic face hosted model and mad that into a plumbing family. Aug 13, 2009 · I have created a clock/speaker family using the "Electrical Fixture wall based" template. A face host family is way more flexible. how can i get a face based family (I would settle for making it wall based, since I can convert that one to face-based) #15: Convert a face-based family to non-hosted Generally speaking, you cannot convert one kind of family to another. Go back to your issue. I was wondering if there was a way to convert a ceiling based family, like an air terminal, to a face based familt for use with a linked model. It will make the family bit heavier but should do what you're after. With these families, there is always a generic model extrusion to represent the face. the problem I have with my R2022 family (attached) is that I can't delete that host. Face Based? Currently we draw our reference planes at the architectural ceiling elevation and host our light fixtures and any other ceiling mouted devices to that plane. Families created from the template can make complex cuts in hosts. I know how to convert a wall or ceiling based family to a face based family. This process might cause a few issues, so be careful. So, here’s the Apr 27, 2011 · I am planning on revamping my office Families content, one of the things I always fighting is whether the family is hosted or free-standing (non-hosted). You'll see how to convert the hosted family to a face-based family using the Copy/Monitor tool. **Edit** Accepted a "solution" but it's really more of a work-around for what I consider a bug in Revit 2023. May 5, 2009 · Face Based, is a hosted family. If you are using Revit the way Autodesk thinks it works; One single model shared by all disciplines (somehow) - Hosted families will work. Today We will learn How to Convert Wall , Ceiling, Floor Based family to Face based family. Sep 7, 2018 · 2. This would help immensely with modifying and reusing complex models for the specific issues of a project. Host based reference planes would be converted to normal reference planes. Aug 28, 2013 · We are about to begin a new project in Revit MEP 2014. Choose Collaborate, Changing a Revit family host is a lot of work and often requires the recreation of the family with a different family template. Jul 25, 2023 · The face based family that @ToanDN created and shared works as expected in your file, either hosted by a wall face in the project or a wall face in a linked model. Once a Revit link is in the project, you can Bind Link to convert it to a group. Dec 2, 2021 · How to create a light fixture family that is face based instead of wall based. This is how you do it. No need to rebuild it as a face based. If your floor is already in place select Face, otherwise Work Plane will get you what you need. Use the face-based template to create work plane-based families that can modify their hosts. Instances of these families can be placed on any surface, regardless of its orientation. May 20, 2021 · 1. You can also convert a Wall-Based Family to a Face-Based Family with the following steps: 1. 3. Aubin for an in-depth discussion in this video, Convert a hosted family to face-based or non-hosted family, part of Revit: Tips, Tricks, and Troubleshooting. Join Paul F. They should be on the exterior face, the control points are on the exterior face, but they come in on the interior Feb 18, 2018 · Either should work. You should see some options in the context tab to select Vertical Face (i. Decide which of the families need to be changed. I've seen multiple videos showing the process of switching the family to either a airport terminal or mechanical equipment etc, linking and copy/monitoring to create an face-based instance. If it's hosted on Wall/Ceiling/Floor. For wall mounted object, such as trash receptacle, recess fixture that need to cut out the host (wall), most people (including myself) will go for face based other than wall Nest that loose family into a wall based, and link parameters. Dec 11, 2015 · To host families on elements in linked files, you need face-based families. The reverse is also possible. Nov 7, 2020 · Revit Beginners Must know in MEP How To Convert Diffuser Hosted Ceiling Based Family to Non-Hosted Mar 2, 2020 · Nest the non-hosted family into a Generic Model Wall Hosted family template. Revit Family to Revit Project. If you are using Revit the way everyone in the world actually uses Revit; Each discipline has their own model and links to each others - Create face based or non-hosted families. Not really, no. But the problem arises when I copied the shower cabin to the other floors, some of them directly hosted to the floor level which is 200 mm rise, but some hosted to the level which is 0 mm elevation. I have ensured that both families are non-hosted (both by seeing that the “host” parameter in the family is blank, and by linking/copy/monitor the families per the convert-hosted-to-unhosted hacks I’ve seen elsewhere). Oct 8, 2023 · Place an instance of both families inside the host project. . ArgumentException: Family cannot be Dec 9, 2010 · I am planning on revamping my office Families content, one of the things I always fighting is whether the family is hosted or free-standing (non-hosted). Mar 19, 2014 · So the highly-intuitive process (sarcasm anyone?) of taking a family that is built in a hosted template such as face-based, wall-based, ceiling-based, etc. You may have to tab around to get to the correct face, but it can be done. It is available in Revit MEP or in Revit 2013 One Box. Then you will get the option to Place on Face or Place on Workplane. Revit's out of the box wall-hosted toilets, for example, are a pointlessly hosted family that quickly gets annoying to use solely because it's hosted. a. You mention that face based families do not cut holes. Go wall by wall, selecting all elements, and PH (pick host, I think), and place them anew. com/CAD Point LinkedIn Dec 9, 2010 · As Aaron pointed out (albeit the other way around), when in the family environment, non-hosted sinks will not cut the countertops at all,; while face-based sinks appear to cut the countertops in the family, until you load it into the project - then they un-cut. The hanging elements can be adjusted to meet the sloped ceiling by several methods: - if a single rod or wire, use an instance parameter to stretch it to meet the ceilng Jan 17, 2015 · The Kohler families are face based and face based families default to a vertical surface when you insert them into a project. That means neither option works in the family environment. Line-based is not. So in this case, I have two faucet part families (ideally unhosted, currently face based) --> nested into a faucet family (currently unhosted) --> nested into the final combination lavatory and faucet family (currently face based with a void to cut the countertop). Problem is the architect's are Level based, ours are all face based so the orientation of the geometry comes in wrong as per the image. Those fixtures are face-based, and are basically the same fixtures, but with a different kind of host. Revit currently doesn't support converting a wall-based Aug 22, 2021 · . Dec 31, 2012 · Another good option is, if possible, is to use families from the MEP folder of the Lighting fixtures folder in the library (If you have that folder, of course). Exceptions. is it possible? Aug 28, 2021 · Revit Revit Families Revit Tips Uncategorized August 28, 2021 🔰In this video, we will learn how to Convert Revit Hosted Families to Face Based Family or Non-Hosted Family In the modelling process, it is very common to receive some families that are Wall based or Ceiling based but actually, its is annoying sometimes but don’t worry we can Jul 14, 2017 · The reason for this is that the electrical socket family was created as a Wall Based: So how do you change the hosting in a family so that it can be place elsewhere? Well, what you can’t do is open the family and change it there, as in the Family Category and Parameters, you will see the Host parameter and value greyed-out. mepguy. TIP: uncheck "Always Vertical" and check "Work Plane-Based" in family before nesting. Affected families can include Face based families such as electrical, lighting and security devices. Dec 28, 2019 · We explore the idea of converting a faced based family to a Level-Based (Non-Hosted Family) May 21, 2023 · Learn how to change a hosted family to a non-hosted family in Revit with this short video tutorial. When you load it to the Revit project and place on any surface, it cuts host element automatically. wall), Face or Work Plane. Apr 30, 2018 · Hi, I’m trying to insert face based families through dynamo. I can move it up or down with the move tool as well as enter different values in the Elevation from level parameter, even changing the Schedule Level parameter. So, if you want to change the offset and keeping the association with its host, set the offset distance by parameter in the family. NewFamilyInstance(inferiorFaceRef,location,refDir, familySymbol); -----Autodesk. If you want to cut host element automatically at the moment of face-based void placement, you have to cut the host element first. Sep 6, 2018 · Hey guys, I’m searching for a method to replace familyinstances (of the same category). As well with non-host, you can change it to workplane, this will turn your door to host on surface or workplane. You can insert multiple ones at the same time; Save the file and close it; Jan 10, 2018 · Hi. But is it really necessary? I found that often just placing a light fixture is already clear enough for other parties that at that location a hole will be needed. You can host a non-hosted family inside of a hosted one. If you set the category to an Electrical Fixture family you can select the family and the described method works great. Generic family are Windows, door ( Wall based ), Light fixtures ( Ceiling based ), Plumbing or furniture ( Floor Based ) Sep 19, 2017 · I think each option has it's usefulness, it just depends on the family. Revit. Here's a quick workaround to Jan 18, 2018 · Guys ive been stuck on this trawling through forums for half a day! and i'm sure its something fairly simple. Nov 29, 2023 · Changing wall-based families to face-based families as there is no direct way to convert them in Revit. If it is already modelled as upright when placed on floor you might want to also set it to "Always Vertical" so that it doesnt rotate 90 degrees when placed on a wall. Fellow Expert Elite Karam Baki has posted an interesting workaround for ‘converting’ between differently hosted Revit families. com/ Dec 11, 2023 · Copymonitor the family from the linked model when you have the host model open (this will convert to face) Edit the copyminotored family. Sep 15, 2021 · Стъпки за премахване на host-зависимостта на Revit фамилии. Last night I discovered the answer. But I’m not able to get the reference plane or face for placing the new instances correctly. There is an exception for face-based families. Jun 23, 2022 · You will need to enter a name to the linked Revit file. Feb 3, 2009 · If you build the light as a Face-Based family, it can be placed on ANY face of any object. Jun 20, 2023 · I am referring to do in the the family environment, not in the project, change the host definition of the family, the non hosted family can be hosted in a face and a work plane but it does not behave the same as a Face based family Jan 30, 2017 · Convert Family from Wall to Face based. After long years of work we have Revit family library which we us Apr 30, 2021 · You don't have to. Back in 2011 I posted about some related workflows, including the necessary steps to get System family elements in a normal Component family: Save an In-Place Family as an RFA for use in another project Create a Component Family with Category set to Walls (or other system family category) Feb 8, 2019 · Provide an option to convert a hosted family to a non-hosted family without breaking parameters and constraints. I’ve tried to get the points of the existing instances and place the new instances by this information. Adding an Attached Detail Group. You use a fixture that is hosted to a Level and then you can set the offset for each instance as you desire. Jan 12, 2016 · But you can use the Cut tool and select host element, then void, and then you will have a cut there. Jan 5, 2017 · 4-Still use face based families (or non-hosted). I came across this post about switching lighting families from wall hosted to face-based and with a little tweak, made it work for casework. Other than my own insanity? Not really. Jul 14, 2011 · You simply can not select a wallbased family of the window category with copy monitor. 4. Delete the facr plane and uncheck the workplane based family checkbox in the properties. Oct 28, 2022 · thanks for the reply. There are multiple family categories in Revit which can be set to both wall-based or face-based. The Wall based families have already a host object in the family (wall) and can, with this method, be changed to a face object in the family. Any better ideas About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jun 25, 2013 · Please help : Changing Non- Host Revit Family to Face based or Wall BAsed Host Family I know how to convert a wall or ceiling based family to a face based family. After the conversion to face based you can set the category back to window. When you place it, open the reflected ceiling plan and choose Face instead of Vertical face to place it on a ceiling. Save the Project somewhere. and when load the family in, you need to manually use "cut geometry Dec 4, 2016 · HI, I have created a host based air terminal. Jul 26, 2017 · I forgot to mention that when you move a face based equipment off the host, it will become non-host. I got it to work using the “FamilyInstance. What you can do is create a non-host family with nested void, however you must check "cut with void when loaded" in family category. But yeah Jul 9, 2019 · Convert a Hosted Family to Face-Based or Non-Hosted Family in Revit | Revit This video shows how to change a hosted family to a type that Revit can monitor. Discover the benefits and drawbacks of each type of family and how to use them effectively in Aug 9, 2011 · About the best you can do is nest the hosted (assuming it's only face based) into the non-hosted and re-link parameters. I would like to know how can I change this to non hosted family Решено: I have created a face based hosted family. Create a new Project, draw a Wall, and load the Family into it. By using Ideate BIMLink to change coordinates data in excel and then import that back into Revit it is possible to change one family type for another family Mar 2, 2017 · Please allow changing the hosting parameter of a Family - for example we have Floor based families and it is not easy to change the hosting to Face based or something else Mar 16, 2021 · Correct me if I'm wrong, but I think the wall/ceiling etc. Use Face based or workplane base family: - host the family on a face or a ref plane - the family can be rotated on the ref plane - the ref plane itself can be rotated . I can go into a Section and designate the ceiling face as the current Work Plane and then place the fixtures. Note: A face-based family is required to host the family on a linked Revit model. But I can't imagine a case where limiting a face-based family to wall, or floor or ceiling is good. Generic Family are helpful, custom face based etc wont talk to the host in parametric terms. This is done by deleting the host. This usually means its a family that is hosted to a Level. And for that one the above trick doens't create a face-based family. Nov 21, 2018 · Use the copy monitor trick to convert it to face based family. Note the difference in creating the element: If a family is workplane based, Revit will prompt you to pick a face or a workplane as a host before actually placing the element in the model. Use a non host or work plane base family and place it on a project level with an offset height (bottom of fixture AFF). e. It seems that reference planes don’t What is a face based family Revit? Face-based. But if you insist, create another ceiling hosted family of the same category and nest the face hosted family in, then associate parameters if need be. I have tried placing it in 3d or in ceiling view but nothing works. Thanks for the link but unfortunately, that method won't work to change un-hosted to face based. &nbsp; Jan 19, 2012 · any luck in converting face based to non-host (or work plane based), manually or automatically, well, even manually getting rid of that host (extrusion) doesn't mean a real non-host (or work plane based), for instance , no Offset parameter Floor Based Hosted Family In Revit EXPLAINED Jun 23, 2017 · Any family that DOES have the ability specify an offset (or mounting height) has to - logically - know its offset FROM something. I have downloaded a shower cabin family in revit and inserted into my multi story building. Place one instance of each Type of that Family on the Wall. I tend to not use any -based families, because they almost always end up doing something strange or annoying. There are two group types in Revit: model groups and detail groups. It gets extremely finicky if you are trying to host a recessed light on objects thicker than a typical ceiling though. Jun 21, 2007 · If I create a hosted family and want to be able to have the family offset from the host face by some distance, I will usually add a reference plane with a dimension and give it an "offset" parameter, and then lock the family to that plane. Aug 29, 2021 · These instructions (after 10 minutes in the video) show how to convert a face-hosted family into a non-hosted family. omgxf engv shap ibu keh bry byayyk tdmzbgbb cijaim ojlvzt